Weight | 0.06 g |
---|---|
Dimensions | 68 × 95 × 25 mm |
Description |
Passive current transducer 100 A dc for 4-20 mA current loop |
Input |
Monopolar 0..10 A, 0..25 A, 0..50 A, 0..100 A, bipolar -10..0..+10 A, -25..0..+25 A, -10..0..+50 A, -25..0..+100 A |
Power Supply |
4-20 mA passive current loop |
Accuracy |
Better than 0.2% |
Internal Consumption |
< 50mW |
Insulation |
1,5 kVdc on raw conductor |
Conductor |
17.8mm Hole for conductor |
T201DC 100A DC Current Transformer
Passive current transducer 100 Adc for 4..20 mA current loop
T01DC100 is an isolated and passive, contact-less loop powered direct current transducer. The T201DC100 has functions and look very similar to a standard current transformer, but it has additional feature of measuring continuous current component that pass-through it.
Additional information
Related products
T201DCH300-M 300A AC/DC Current Transformer
AC/DC contactless TRMS current (± 300 A) transducer, Hall Effect
T201DCH300-M is an isolated, contact-less loop powered AC/DC current transducer with ModBUS interface and very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current
.
T201DCH100-M 100A AC/DC Current Transformer
AC/DC contactless TRMS current transducer with ModBUS interface
T201DCH50-M is an isolated, contact-less direct and alternating TRMS current transducer with ModBUS interface. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
T201 40A AC Current Transformer
Loop-powered AC current transducer
T201 is an AC current transducer (CT) for 4..20 mA current loops (loop powered). The module's main features are high precision, extremely compact size and wide configurability: eight pre-calibrated ranges, DIP-switch selected. T201 allows extremely low consumption and low output ripple and quick response to variations.
T201DCH50-M 50A AC/DC Current Transformer
AC/DC contactless TRMS current transducer with ModBUS interface
T201DCH50-M is an isolated, contact-less direct and alternating TRMS current transducer with ModBUS interface. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
T201DCH50-LP 50A AC/DC Current Transformer
AC/DC contactless TRMS AC/DC transducer with 4-20 mA output
T201DCH50-LP is an isolated, contact-less direct and alternating TRMS current transducer. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
T201DCH300 300A AC/DC Current Transformer
AC/DC contactless TRMS current (± 300 A) transducer, Hall Effect
T201DCH300 is an isolated, contact-less loop powered AC/DC current transducer with very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current. For its electrical endurance, ease of use and compact dimensions,
T201DCH100-LP 100A AC/DC Current Transformer
AC/DC contactless TRMS current (± 100 A) transducer, Hall Effect with 4-20 mA Output
T201DCH100-LP is an isolated, contact-less loop powered AC/DC current transducer with very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current.
T201DCH 50A AC/DC Current Transformer
AC/DC contactless TRMS current transducer