Weight | 0.06 g |
---|---|
Dimensions | 38 × 40 × 20 mm |
Description |
DC Current Transducer to DC current (4-20 mA – loop powered) |
Input |
8 selectable scales mono/bi-polar via DIP-switch from ±5 A to 40 A (continuous) |
Power Supply |
4-20mA Loop Powered |
Accuracy |
Better than 0.2% |
Internal Consumption |
< 50mW |
Connection |
Direct without external shunt (also for current pulses) |
Extended Loop Voltage |
6-100V |
T201DC 40A AC Current Transformer
DC loop powered 4-20 mA current transducer
T201DC is an isolated, contact-less loop powered direct current transducer. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
Additional information
Related products
T201DCH300-LP 300A AC/DC Current Transformer
AC/DC contactless TRMS current (± 300 A) transducer, Hall Effect with 4-20 mA Output
T201DCH300-LP is an isolated, contact-less loop powered AC/DC current transducer with very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current.
T201DCH100-M 100A AC/DC Current Transformer
AC/DC contactless TRMS current transducer with ModBUS interface
T201DCH50-M is an isolated, contact-less direct and alternating TRMS current transducer with ModBUS interface. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
T201DCH100-LP 100A AC/DC Current Transformer
AC/DC contactless TRMS current (± 100 A) transducer, Hall Effect with 4-20 mA Output
T201DCH100-LP is an isolated, contact-less loop powered AC/DC current transducer with very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current.
T201DCH300-M 300A AC/DC Current Transformer
AC/DC contactless TRMS current (± 300 A) transducer, Hall Effect
T201DCH300-M is an isolated, contact-less loop powered AC/DC current transducer with ModBUS interface and very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current
.
T201DCH50-LP 50A AC/DC Current Transformer
AC/DC contactless TRMS AC/DC transducer with 4-20 mA output
T201DCH50-LP is an isolated, contact-less direct and alternating TRMS current transducer. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
T201DCH50-M 50A AC/DC Current Transformer
AC/DC contactless TRMS current transducer with ModBUS interface
T201DCH50-M is an isolated, contact-less direct and alternating TRMS current transducer with ModBUS interface. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.
T201DCH100 100A AC/DC Current Transformer
AC/DC contactless TRMS current (± 100 A) transducer, Hall Effect with 0..10 V AO
T201DCH100 is an isolated, contact-less loop powered AC/DC current transducer with very compact size (overall dimensions less than 96,5 x 68 x 26 mm). The device function and look is very similar to those of an active standard CT, but with the remarkable feature of measuring the TRMS DC and AC component of the current. For its electrical endurance, ease of use and compact dimensions,
T201DCH 50A AC/DC Current Transformer
AC/DC contactless TRMS current transducer
T201DCH is an isolated, contact-less direct and alternating TRMS current transducer. The device’s function and look are very similar to those of an active standard CT, but with the remarkable feature of measuring the continuous component of the pass-trough current.