Weight | 0.2 g |
---|---|
Dimensions | 100 × 17.5 × 112 mm |
Power Supply |
85-265 V ac |
Max Internal Consumption |
<1.5W |
Insulation |
3750 V ac (input/output, input/power supply), 1500 V ac (output/power supply) |
Ingress Protection |
IP20 |
Response Time |
<100ms |
Accuracy |
0.3% |
Input Channels |
1 – Voltage (Single Phase) |
Input Range |
0-500 V ac, Input Impedance 2000 Ω/V, Frequency 10Hz – 1KHz |
Output Channels |
1 – Current/Voltage |
Output Range |
0-20mA / 4-20mA (max load 600Ω), 0-5V dc, 0-10 V dc, 1-5 V dc, 2-10 V dc (min load 2500Ω) |
Mounting |
DIN Rail (35mm) |
Configuration |
DIP switch |
Connections |
Removable Screw Terminals |
Approvals |
EN 61000-6-4, EN 61000-6-2, EN 61010-1 |
Z202-H
AC voltage to DC Isolator converter
Z202 accept an alternate voltage (10..490 Vac) and provides an isolated analog output (mA or V). Z202 can be used as a micro-ammeter (500 µAfs), A 3-way galvanic isolation between Power supply | input | output circuits
Additional information
Related products
Z201
Z202-LP
AC voltage to DC Isolator converter
Z202-LP is an universal converter for AC or DC voltages (0..500 Vac or 0..540 Vdc) and provides an isolated 4..20mA output. It’s a loop powered device through the 4..20mA loop output. Z202-LP provides galvanic isolation between Power supply | input | output circuitsZ201-H
Z202
Z204-1
S201RC-LP Rogowski sensors converter loop-powered
S201RC-LP is a loop powered converter suitable for ac current measurements coupled with Rogowski sensors. This converter is characterized by low consumption (<0.6 W) and works with a sensor that provides 100 mV/kA as output signal for TRMS measurements. The input scales are selectable as 250, 500, 1.000, 2.000, 4.000 A